dd(1p) — Linux manual page
DD(1P) POSIX Programmer's Manual DD(1P)
PROLOG
This manual page is part of the POSIX Programmer's Manual. The
Linux implementation of this interface may differ (consult the
corresponding Linux manual page for details of Linux behavior),
or the interface may not be implemented on Linux.
NAME
dd — convert and copy a file
SYNOPSIS
dd [operand...]
DESCRIPTION
The dd utility shall copy the specified input file to the
specified output file with possible conversions using specific
input and output block sizes. It shall read the input one block
at a time, using the specified input block size; it shall then
process the block of data actually returned, which could be
smaller than the requested block size. It shall apply any
conversions that have been specified and write the resulting data
to the output in blocks of the specified output block size. If
the bs=expr operand is specified and no conversions other than
sync, noerror, or notrunc are requested, the data returned from
each input block shall be written as a separate output block; if
the read returns less than a full block and the sync conversion
is not specified, the resulting output block shall be the same
size as the input block. If the bs=expr operand is not specified,
or a conversion other than sync, noerror, or notrunc is
requested, the input shall be processed and collected into full-
sized output blocks until the end of the input is reached.
The processing order shall be as follows:
1. An input block is read.
2. If the input block is shorter than the specified input block
size and the sync conversion is specified, null bytes shall
be appended to the input data up to the specified size. (If
either block or unblock is also specified, <space> characters
shall be appended instead of null bytes.) The remaining
conversions and output shall include the pad characters as if
they had been read from the input.
3. If the bs=expr operand is specified and no conversion other
than sync or noerror is requested, the resulting data shall
be written to the output as a single block, and the remaining
steps are omitted.
4. If the swab conversion is specified, each pair of input data
bytes shall be swapped. If there is an odd number of bytes in
the input block, the last byte in the input record shall not
be swapped.
5. Any remaining conversions (block, unblock, lcase, and ucase)
shall be performed. These conversions shall operate on the
input data independently of the input blocking; an input or
output fixed-length record may span block boundaries.
6. The data resulting from input or conversion or both shall be
aggregated into output blocks of the specified size. After
the end of input is reached, any remaining output shall be
written as a block without padding if conv=sync is not
specified; thus, the final output block may be shorter than
the output block size.
OPTIONS
None.
OPERANDS
All of the operands shall be processed before any input is read.
The following operands shall be supported:
if=file Specify the input pathname; the default is standard
input.
of=file Specify the output pathname; the default is standard
output. If the seek=expr conversion is not also
specified, the output file shall be truncated before
the copy begins if an explicit of=file operand is
specified, unless conv=notrunc is specified. If
seek=expr is specified, but conv=notrunc is not, the
effect of the copy shall be to preserve the blocks in
the output file over which dd seeks, but no other
portion of the output file shall be preserved. (If the
size of the seek plus the size of the input file is
less than the previous size of the output file, the
output file shall be shortened by the copy. If the
input file is empty and either the size of the seek is
greater than the previous size of the output file or
the output file did not previously exist, the size of
the output file shall be set to the file offset after
the seek.)
ibs=expr Specify the input block size, in bytes, by expr
(default is 512).
obs=expr Specify the output block size, in bytes, by expr
(default is 512).
bs=expr Set both input and output block sizes to expr bytes,
superseding ibs= and obs=. If no conversion other than
sync, noerror, and notrunc is specified, each input
block shall be copied to the output as a single block
without aggregating short blocks.
cbs=expr Specify the conversion block size for block and unblock
in bytes by expr (default is zero). If cbs= is omitted
or given a value of zero, using block or unblock
produces unspecified results.
The application shall ensure that this operand is also
specified if the conv= operand is specified with a
value of ascii, ebcdic, or ibm. For a conv= operand
with an ascii value, the input is handled as described
for the unblock value, except that characters are
converted to ASCII before any trailing <space>
characters are deleted. For conv= operands with ebcdic
or ibm values, the input is handled as described for
the block value except that the characters are
converted to EBCDIC or IBM EBCDIC, respectively, after
any trailing <space> characters are added.
skip=n Skip n input blocks (using the specified input block
size) before starting to copy. On seekable files, the
implementation shall read the blocks or seek past them;
on non-seekable files, the blocks shall be read and the
data shall be discarded.
seek=n Skip n blocks (using the specified output block size)
from the beginning of the output file before copying.
On non-seekable files, existing blocks shall be read
and space from the current end-of-file to the specified
offset, if any, filled with null bytes; on seekable
files, the implementation shall seek to the specified
offset or read the blocks as described for non-seekable
files.
count=n Copy only n input blocks. If n is zero, it is
unspecified whether no blocks or all blocks are copied.
conv=value[,value ...]
Where values are <comma>-separated symbols from the
following list:
ascii Convert EBCDIC to ASCII; see Table 4-7, ASCII
to EBCDIC Conversion.
ebcdic Convert ASCII to EBCDIC; see Table 4-7, ASCII
to EBCDIC Conversion.
ibm Convert ASCII to a different EBCDIC set; see
Table 4-8, ASCII to IBM EBCDIC Conversion.
The ascii, ebcdic, and ibm values are mutually-
exclusive.
block Treat the input as a sequence of
<newline>-terminated or end-of-file-terminated
variable-length records independent of the
input block boundaries. Each record shall be
converted to a record with a fixed length
specified by the conversion block size. Any
<newline> shall be removed from the input
line; <space> characters shall be appended to
lines that are shorter than their conversion
block size to fill the block. Lines that are
longer than the conversion block size shall be
truncated to the largest number of characters
that fit into that size; the number of
truncated lines shall be reported (see the
STDERR section).
The block and unblock values are mutually-
exclusive.
unblock Convert fixed-length records to variable
length. Read a number of bytes equal to the
conversion block size (or the number of bytes
remaining in the input, if less than the
conversion block size), delete all trailing
<space> characters, and append a <newline>.
lcase Map uppercase characters specified by the
LC_CTYPE keyword tolower to the corresponding
lowercase character. Characters for which no
mapping is specified shall not be modified by
this conversion.
The lcase and ucase symbols are mutually-
exclusive.
ucase Map lowercase characters specified by the
LC_CTYPE keyword toupper to the corresponding
uppercase character. Characters for which no
mapping is specified shall not be modified by
this conversion.
swab Swap every pair of input bytes.
noerror Do not stop processing on an input error. When
an input error occurs, a diagnostic message
shall be written on standard error, followed
by the current input and output block counts
in the same format as used at completion (see
the STDERR section). If the sync conversion is
specified, the missing input shall be replaced
with null bytes and processed normally;
otherwise, the input block shall be omitted
from the output.
notrunc Do not truncate the output file. Preserve
blocks in the output file not explicitly
written by this invocation of the dd utility.
(See also the preceding of=file operand.)
sync Pad every input block to the size of the ibs=
buffer, appending null bytes. (If either block
or unblock is also specified, append <space>
characters, rather than null bytes.)
The behavior is unspecified if operands other than conv= are
specified more than once.
For the bs=, cbs=, ibs=, and obs= operands, the application shall
supply an expression specifying a size in bytes. The expression,
expr, can be:
1. A positive decimal number
2. A positive decimal number followed by k, specifying
multiplication by 1024
3. A positive decimal number followed by b, specifying
multiplication by 512
4. Two or more positive decimal numbers (with or without k or b)
separated by x, specifying the product of the indicated
values
All of the operands are processed before any input is read.
The following two tables display the octal number character
values used for the ascii and ebcdic conversions (first table)
and for the ibm conversion (second table). In both tables, the
ASCII values are the row and column headers and the EBCDIC values
are found at their intersections. For example, ASCII 0012 (LF) is
the second row, third column, yielding 0045 in EBCDIC. The
inverted tables (for EBCDIC to ASCII conversion) are not shown,
but are in one-to-one correspondence with these tables. The
differences between the two tables are highlighted by small boxes
drawn around five entries.
Table 4-7: ASCII to EBCDIC Conversion
Table 4-8: ASCII to IBM EBCDIC Conversion
STDIN
If no if= operand is specified, the standard input shall be used.
See the INPUT FILES section.
INPUT FILES
The input file can be any file type.
ENVIRONMENT VARIABLES
The following environment variables shall affect the execution of
dd:
LANG Provide a default value for the internationalization
variables that are unset or null. (See the Base
Definitions volume of POSIX.1‐2017, Section 8.2,
Internationalization Variables for the precedence of
internationalization variables used to determine the
values of locale categories.)
LC_ALL If set to a non-empty string value, override the values
of all the other internationalization variables.
LC_CTYPE Determine the locale for the interpretation of
sequences of bytes of text data as characters (for
example, single-byte as opposed to multi-byte
characters in arguments and input files), the
classification of characters as uppercase or lowercase,
and the mapping of characters from one case to the
other.
LC_MESSAGES
Determine the locale that should be used to affect the
format and contents of diagnostic messages written to
standard error and informative messages written to
standard output.
NLSPATH Determine the location of message catalogs for the
processing of LC_MESSAGES.
ASYNCHRONOUS EVENTS
For SIGINT, the dd utility shall interrupt its current
processing, write status information to standard error, and exit
as though terminated by SIGINT. It shall take the standard action
for all other signals; see the ASYNCHRONOUS EVENTS section in
Section 1.4, Utility Description Defaults.
STDOUT
If no of= operand is specified, the standard output shall be
used. The nature of the output depends on the operands selected.
STDERR
On completion, dd shall write the number of input and output
blocks to standard error. In the POSIX locale the following
formats shall be used:
"%u+%u records in\n", <number of whole input blocks>,
<number of partial input blocks>
"%u+%u records out\n", <number of whole output blocks>,
<number of partial output blocks>
A partial input block is one for which read() returned less than
the input block size. A partial output block is one that was
written with fewer bytes than specified by the output block size.
In addition, when there is at least one truncated block, the
number of truncated blocks shall be written to standard error. In
the POSIX locale, the format shall be:
"%u truncated %s\n", <number of truncated blocks>, "record" (if
<number of truncated blocks> is one) "records" (otherwise)
Diagnostic messages may also be written to standard error.
OUTPUT FILES
If the of= operand is used, the output shall be the same as
described in the STDOUT section.
EXTENDED DESCRIPTION
None.
EXIT STATUS
The following exit values shall be returned:
0 The input file was copied successfully.
>0 An error occurred.
CONSEQUENCES OF ERRORS
If an input error is detected and the noerror conversion has not
been specified, any partial output block shall be written to the
output file, a diagnostic message shall be written, and the copy
operation shall be discontinued. If some other error is detected,
a diagnostic message shall be written and the copy operation
shall be discontinued.
The following sections are informative.
APPLICATION USAGE
The input and output block size can be specified to take
advantage of raw physical I/O.
There are many different versions of the EBCDIC codesets. The
ASCII and EBCDIC conversions specified for the dd utility perform
conversions for the version specified by the tables.
EXAMPLES
The following command:
dd if=/dev/rmt0h of=/dev/rmt1h
copies from tape drive 0 to tape drive 1, using a common
historical device naming convention.
The following command:
dd ibs=10 skip=1
strips the first 10 bytes from standard input.
This example reads an EBCDIC tape blocked ten 80-byte EBCDIC card
images per block into the ASCII file x:
dd if=/dev/tape of=x ibs=800 cbs=80 conv=ascii,lcase
RATIONALE
The OPTIONS section is listed as ``None'' because there are no
options recognized by historical dd utilities. Certainly, many of
the operands could have been designed to use the Utility Syntax
Guidelines, which would have resulted in the classic hyphenated
option letters. In this version of this volume of POSIX.1‐2017,
dd retains its curious JCL-like syntax due to the large number of
applications that depend on the historical implementation.
A suggested implementation technique for conv=noerror,sync is to
zero (or <space>-fill, if blocking or unblocking) the input
buffer before each read and to write the contents of the input
buffer to the output even after an error. In this manner, any
data transferred to the input buffer before the error was
detected is preserved. Another point is that a failed read on a
regular file or a disk generally does not increment the file
offset, and dd must then seek past the block on which the error
occurred; otherwise, the input error occurs repetitively. When
the input is a magnetic tape, however, the tape normally has
passed the block containing the error when the error is reported,
and thus no seek is necessary.
The default ibs= and obs= sizes are specified as 512 bytes
because there are historical (largely portable) scripts that
assume these values. If they were left unspecified, unusual
results could occur if an implementation chose an odd block size.
Historical implementations of dd used creat() when processing
of=file. This makes the seek= operand unusable except on special
files. The conv=notrunc feature was added because more recent
BSD-based implementations use open() (without O_TRUNC) instead of
creat(), but they fail to delete output file contents after the
data copied.
The w multiplier (historically meaning word), is used in System V
to mean 2 and in 4.2 BSD to mean 4. Since word is inherently non-
portable, its use is not supported by this volume of
POSIX.1‐2017.
Standard EBCDIC does not have the characters '[' and ']'. The
values used in the table are taken from a common print train that
does contain them. Other than those characters, the print train
values are not filled in, but appear to provide some of the
motivation for the historical choice of translations reflected
here.
The Standard EBCDIC table provides a 1:1 translation for all 256
bytes.
The IBM EBCDIC table does not provide such a translation. The
marked cells in the tables differ in such a way that:
1. EBCDIC 0112 ('¢') and 0152 (broken pipe) do not appear in the
table.
2. EBCDIC 0137 ('¬') translates to/from ASCII 0236 ('^'). In
the standard table, EBCDIC 0232 (no graphic) is used.
3. EBCDIC 0241 ('~') translates to/from ASCII 0176 ('~'). In
the standard table, EBCDIC 0137 ('¬') is used.
4. 0255 ('[') and 0275 (']') appear twice, once in the same
place as for the standard table and once in place of 0112
('¢') and 0241 ('~').
In net result:
EBCDIC 0275 (']') displaced EBCDIC 0241 ('~') in cell
0345.
That displaced EBCDIC 0137 ('¬') in cell 0176.
That displaced EBCDIC 0232 (no graphic) in cell 0136.
That replaced EBCDIC 0152 (broken pipe) in cell 0313.
EBCDIC 0255 ('[') replaced EBCDIC 0112 ('¢').
This translation, however, reflects historical practice that
(ASCII) '~' and '¬' were often mapped to each other, as were '['
and '¢'; and ']' and (EBCDIC) '~'.
The cbs operand is required if any of the ascii, ebcdic, or ibm
operands are specified. For the ascii operand, the input is
handled as described for the unblock operand except that
characters are converted to ASCII before the trailing <space>
characters are deleted. For the ebcdic and ibm operands, the
input is handled as described for the block operand except that
the characters are converted to EBCDIC or IBM EBCDIC after the
trailing <space> characters are added.
The block and unblock keywords are from historical BSD practice.
The consistent use of the word record in standard error messages
matches most historical practice. An earlier version of System V
used block, but this has been updated in more recent releases.
Early proposals only allowed two numbers separated by x to be
used in a product when specifying bs=, cbs=, ibs=, and obs=
sizes. This was changed to reflect the historical practice of
allowing multiple numbers in the product as provided by Version 7
and all releases of System V and BSD.
A change to the swab conversion is required to match historical
practice and is the result of IEEE PASC Interpretations 1003.2
#03 and #04, submitted for the ISO POSIX‐2:1993 standard.
A change to the handling of SIGINT is required to match
historical practice and is the result of IEEE PASC Interpretation
1003.2 #06 submitted for the ISO POSIX‐2:1993 standard.
FUTURE DIRECTIONS
None.
SEE ALSO
Section 1.4, Utility Description Defaults, sed(1p), tr(1p)
The Base Definitions volume of POSIX.1‐2017, Chapter 8,
Environment Variables
COPYRIGHT
Portions of this text are reprinted and reproduced in electronic
form from IEEE Std 1003.1-2017, Standard for Information
Technology -- Portable Operating System Interface (POSIX), The
Open Group Base Specifications Issue 7, 2018 Edition, Copyright
(C) 2018 by the Institute of Electrical and Electronics
Engineers, Inc and The Open Group. In the event of any
discrepancy between this version and the original IEEE and The
Open Group Standard, the original IEEE and The Open Group
Standard is the referee document. The original Standard can be
obtained online at http://www.opengroup.org/unix/online.html .
Any typographical or formatting errors that appear in this page
are most likely to have been introduced during the conversion of
the source files to man page format. To report such errors, see
https://www.kernel.org/doc/man-pages/reporting_bugs.html .
IEEE/The Open Group 2017 DD(1P)
Pages that refer to this page: iconv(1p)